Quick Arrhythmia Guide
Wandering Atrial Pacemaker

Wandering Atrial Pacemaker EKG tracing
RhythmMay be irregular
RateNormal (60-100 bpm)
P WaveChanging shape and size from beat to beat (at least three different forms)
PR IntervalVariable
QRSNormal (0.06-0.10 sec)
NotesT wave normal. If heart rate exceeds 100 bpm, then rhythm may be multifocal atrial tachycardia (MAP)